10 “EDC Megaterm” Application Software

    Once installed on your computer, this software enables the editing, preparation and control of EDC Driver Unit programs
    and parameters. It also facilitates the allocation and monitoring of control input/output. And its oscilloscope function allows
    for easy confirmation of Motor operation.
    EDC Megaterm can be downloaded for free from the NSK Web site (http://www.nsk.com/).

    RS-232C communication cable is             Personal computer     RS-232C
    available (option).
    Type: M-C003RS03 (cable length: 3 [m])      EDC Megaterm                  EDC Driver Unit

                                            Windows 2000 •XP•Vista

    • A USB port can be used on a PC without a COM port. In this case, use a commercial RS-232C/USB conversion
      adaptor for communication. We have confirmed the compatibility of the SRC06-USB, USB serial cable made by Arvel.

    • T he RS-232C communication connector for the EDC Driver Unit has a different pin configuration than that for a PC.

    Functions                               5. Others:
                                            • U pload/download parameter
         1. Oscilloscope function
         2. A llocation and monitoring       and channel data
                                            • Terminal
            of control input/output
         3. Parameter editing
         4. Channel editing

    Main Functions                                                   3. Parameter edits

    1. Oscilloscope function                                             • P arameter edits take effect in real time (off-line editing is
                                                                          also supported)
        • 4-channel oscilloscope, 10 [k sampling/s] maximum
        • A nything that can be monitored using the handy terminal      • Parameter-by-parameter reset to default

          can be displayed on the oscilloscope.                          • Help function for parameters
        • M onitor scales are adjustable.
        • Measured waveforms are output as bitmaps or CSV               • R eport of parameter
                                                                          setting list
          format.

    2. Allocation and monitoring of control input/output             4. Channel edits

        • Allocation of control input/output by drag-and-drop           • Drag-and-drop edits from command window
         editing
                                                                         • D irect input capability also supported (automatic
        • Monitoring of input/output signals                              insertion of comments)